2.1 KINDS OF OPEN CHANNELS
In general, there are two kinds of open channels: (1) natural, and (2) artificial. Natural channels are formed by Nature through geologic, geomorphologic, and hydrologic action. They include all natural watercourses, from the smallest to the largest. An example of a small watercourse is the small stream or rivulet shown in Fig. 2-1. An example of a large watercourse is the large river shown in Fig. 2-2. The largest natural channel is the Amazon river at its mouth, shown in Fig. 2-3. Applications of open-channel hydraulics in natural streams are typically in the fields of flood control, navigation, and stream restoration.
Artificial channels are also referred to as canals. They are made by humans for a specific purpose, usually to transfer water from a place where it exists in ample supply to a place where it is in short supply, or to transfer water between two locations to satisfy daily, monthly, seasonal, or annual requirements. Artificial channels are also built for flood control and navigation. Artificial canals have been built by ancient societies, usually to transfer water for irrigation or water supply. For instance, Fig. 2-4 shows a small canal built about 3,500 years ago by the ancient people of Cajamarca, Peru.
Artificial channels can be referred to with various names, depending on their features and intended use:
Uses of Open Channels Open channels, both natural and artificial, are used in various water resources fields, including:
Figure 2-11 shows a fish-passage channel at a pond-and-plug stream restoration site in Ferris Creek, Plumas County, California.
Related Fields Other related fields that benefit directly from open channel hydraulics knowledge include:
2.2 CHANNEL GEOMETRY
Natural channels refer to the great number of streams and rivers around the world. With respect to longitudinal orientation, natural channels are classified as: (a) straight, (b) meandering, or (c) braided. A straight channel is one that follows more or less a straight path. Conversely, a meandering channel curves around in plan view, as shown in Fig. 2-12. The ratio of stream length to valley length is referred to as sinuosity. The sinuosity of the stream shown is about 4.
A braided channel features multiple interconnected meandering subchannels (Fig. 2-13). The flow and sediment conditions under which a channel assumes a certain longitudinal shape is a subject of fluvial geomorphology.
During floods, natural channels may overflow their banks and temporarily take up significant portions of the adjacent floodplain (Fig. 2-14). With respect to flood stage, flow in natural channels is classified as: (1) inbank, when the flow remains in the main channel, or (2) overbank, when the flow spills over to the adjacent floodplains.
Figure 2-15 shows the typical variation of stage and flood wave travel time K with extent of inundation. These variations are due to relative increases or decreases of surface bottom friction as the stage increases.
Artificial channels are classified as either: (1) prismatic, or (2) nonprismatic. Prismatic channels have a constant cross section, either trapezoidal, rectangular, or triangular. Trapezoidal channels are the most common type (Fig. 2-16). Rectangular channels are often used in sanitary flows and laboratory applications. Triangular channels are normally used in road and urban drainage.
Nonprismatic channels are those for which the cross section is not constant. Nonprismatic channels are used in the transition from a cross section of one size to another of a different size, usually to account for the variability in bottom slope.
Hydraulically wide channel There are three asymptotic cross-sectional shapes in prismatic channels (Section 1.3):
A channel is hydraulically wide when the wetted perimeter P can be approximated by the top width T. By definition, the hydraulic radius R is equal to the flow area A divided by the wetted perimeter P. Likewise, the hydraulic depth D is equal to the flow area A divided by the top width T. Therefore, the following relations hold for a hydraulically wide channel:
In practice, a channel may be considered hydraulically wide if the top width T is greater than or equal to 10 times the hydraulic depth D (Chow, 1959):
In general:
in which Q = discharge, A = flow area, and V = mean velocity. Since by definition:
it follows that:
and:
in which q = discharge per unit of channel width, or unit-width discharge [L2 T -1]. For simplicity, a hydraulically wide channel may be analyzed in terms of its unit-width discharge. For a hypothetical unit-width channel, the wetted perimeter is a constant: P = T = 1. Therefore, a hydraulically wide channel is alternatively defined as that for which the wetted perimeter is a constant. In practice, most natural channels are hydraulically wide (Fig. 2-17).
Exponent of the rating The discharge-flow area rating in open-channel flow is:
The asymptotic values of β are (Section 1.3):
For trapezoidal channels, values of β lie between the
values for hydraulically wide and triangular channels. Typical values of
β for trapezoidal channels lie approximately
in the range
Depth of flow and depth of flow section There are two related depths of open-channel flow (Fig. 2-19):
The depth of flow y is the vertical distance from the free surface to the lowest point in the channel cross section. The depth of flow section d is the distance, normal to the direction of flow, measured from the free surface to the lowest point in the channel cross section.
The relation between depth of flow y and depth of flow section d is:
For the slope angle θ < 8°, the ratio d/y > 0.99. Furthermore, for θ < 2°, the ratio d/y > 0.999. In most cases, the difference between y and d is negligible, warranting the use of y in lieu of d. 2.3 VELOCITY DISTRIBUTION
The mean velocity in open-channel flow is:
Local velocities, however, are likely to vary widely. Vertical velocity profiles vary from zero at the boundary (the no-slip condition at the channel bottom) to values slightly greater than the mean near the water surface (Fig. 2-20).
Transversal velocities are also likely to vary widely, from zero at the side boundaries to maximum values at or near the middle of the channel. In meandering channels, or channels of curved alignment, velocities are larger along the outside of the bend and smaller on the inside. However, for hydraulically wide channels, the sides have negligible influence on the flow. In this case, the flow is effectively two-dimensional (in the longitudinal and vertical directions). The assumption of mean velocity V (Eq. 2-10) further reduces the flow to a statement of one-dimensionality (in the longitudinal direction). This assumption is strictly applicable to channels that are relatively straight and for which flows remain inbank. As a convenient approximation, the one-dimensional assumption has been applied to channels with mild meandering tendencies and limited overbank flows. However, the one-dimensional assumption generally breaks down for channels of large sinuosity and/or substantial overbank flows (Fig. 2-21).
2.4 MEASUREMENTS OF VELOCITY
Measurements of velocity are commonly performed using a current meter. Current meters measure flow velocity by counting the number of revolutions per second of the meter assembly. The rotation can be around a vertical axis, leading to the cup meter, or around a horizontal axis, leading to the propeller meter. Cup meters are widely used in the United States. The most common type of cup meter is the Price current meter, which has six cups mounted on a vertical axis (Fig. 2-22). The flow velocity is proportional to the angular velocity of the meter rotor. The flow velocity is determined by counting the number of revolutions per second of the rotor and consulting the meter calibration table.
Discharge measurements. A discharge measurement at a stream cross section requires the determination of flow area and mean velocity for a given stage. The cross section should be perpendicular to the flow, and mean velocity should be based on a sufficient number of velocity measurements across the section. In a typical stream-gaging procedure, each of several depth soundings, usually 20 to 30, defines the position of a vertical (Fig. 2-23). Each depth sounding is associated with a partial section of the stream. A partial section is a rectangle of depth equal to the sounding and of width equal to half the difference of the distances to adjacent verticals. At each vertical, the following observations are made:
In the two-point method, the current meter is positioned at 0.2 and 0.8 of the flow depth. In the one point method, the current meter is positioned at 0.6 of the flow depth, measured from the water surface. The average of the velocities at 0.2 and 0.8 depth or the single velocity at 0.6 depth is taken as the mean velocity in the vertical. Where a two-point measurement is impractical (e.g., in very shallow streams), the one-point method is recommended. For each partial section, the discharge is calculated as:
in which q = discharge, v = mean velocity, and a = flow area. The total stream discharge Q is the sum of the discharges of each partial section. Price current meters types AA and A are used for two-point velocity measurements in streams with flow depths above 0.75 m and for one-point measurements in streams with depths ranging from 0.45 to 0.75 m. The dwarf (or pigmy) current meter is used for one-point measurements in shallow streams or laboratory flumes with depths in the range 0.10 to 0.45 m. Techniques for measuring stream velocity with a current meter vary with stream size. If the stream is wadable, the meter is affixed to a graduated depth rod. If the stream is too deep to wade, the meter is suspended on a cable and is held in the water with a sounding weight. The weights are made of various sizes, from 6.8 kg to 135 kg. Measurements using cable suspension are made from bridges, cableways, or boats (Fig. 2-24). For the heavier sounding weights or when using a boat, a sounding reel may be required.
2.5 VELOCITY DISTRIBUTION COEFFICIENTS
Due to the nonuniform velocity distribution over a cross section, the true velocity head hv is greater than the velocity head computed based on the mean velocity V. Generally, the true velocity head is:
where in this case α refers to the energy coefficient, or Coriolis coefficient. Values of α range from about 1.03 to 1.36 for fairly straight prismatic channels. The higher values correspond to smaller channels and the lower values to larger channels. Similarly to the case of energy, momentum also requires a correction due to the nonunform velocities. The true expression for momentum flux (force) is:
where in this case β refers to the momentum coefficient, or Boussinesq coefficient; and ρ = mass density of water. Values of β range from about 1.01 to 1.12 for fairly straight prismatic channels.
Values of α and β are slightly greater than 1, with α being always greater than β.
For channels of complex or composite cross sections, values of α and β can easily get as great as
1.6 and 1.2, respectively. In channels of irregular alignment,
α and β may vary widely.
In extreme cases, values of β > 2 have been observed (Chow, 1959).
Assume:
The mean velocity is defined as:
In general, energy is equal to a force integrated over a distance, or force times length:
The kinetic energy for the total area A is equal to mass M times acceleration times distance:
The kinetic energy for the incremental area ΔA is:
The velocity head through ΔA is the kinetic energy per unit of weight, where weight = mg :
The volumetric flux through ΔA is:
The weight flux through ΔA is:
in which γ = unit weight of water.
The incremental kinetic energy flux through ΔA is equal to the kinetic energy per unit of weight hv
The sum of kinetic energy fluxes for all incremental areas is:
The kinetic energy flux through the total area A, based on mean velocity V, is:
Equating Eqs. 2-22 and 2-23, and solving for the Coriolis energy coefficient:
Derivation of the Boussinesq coefficient
The mass flux
J through the total area A is equal to the mass density ρ times the
volumetric flux
The mass flux through the incremental area ΔA is equal to the mass density ρ times the incremental volumetric flux ΔQ = v ΔA:
In general, momentum M is equal to a force integrated over a period of time, or mass times velocity:
The momentum flux, or force F, is equal to the mass flux times the velocity. Thus, the momentum flux through the incremental area ΔA is:
The sum of all momentum fluxes, or sum of forces for all the incremental areas is:
The momentum flux, or force F, through the total area is:
Equating Eqs. 2-29 and 2-30, and solving for the Boussinesq momentum coefficient:
Approximate formulations of α and β While Eqs. 2-24 and 2-31 are accurate, they require detailed measurement of the velocity distribution in the cross section of interest. Alternatively, when only the mean velocity V and maximum velocity Vmax are known, the following formulas may be used to calculate approximate values of the Coriolis and Boussinesq coefficients (Chow, 1959). Defining:
Assuming a logarithmic velocity distribution, the coefficients may be approximated as:
On the other hand, assuming a linear velocity distribution:
2.6 PRESSURE DISTRIBUTION
The
QUESTIONS
PROBLEMS
REFERENCES
Chow, V. T. 1959. Open-channel Hydraulics. McGraw Hill, New York. Ponce, V. M., and D. Windingland. 1985. Kinematic shock: Sensitivity analysis. Journal of Hydraulic Engineering, ASCE, Vol. 111, No. 4, April, 600-611.
|